<LOGO>
FM Transmitter Measurement Report
Created: 2025-11-02 21-42-04
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.20 MHz 5/5, 60 dBuV YLEX
Pilot RDS Phase Difference
7.4 kHz 2.3 kHz 65 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 64 kHz 19098 0,8849
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
0,5 dBr 3,41 dBr 5,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"YLEX " 6202 10 (Pop M) 0 1 1 1 21:42, 2.11.2025
RT
"YleX Vaihtoehto: Raine Laaksonen (u) "
AF EON
91.5, 91.8, 91.9, 92.6, 93.2, 94.3, 96.1 MHz 6207, 6205, 6201, 6203
FM Scope Max at: 64 kHz MIN: 9 kHz % above 76 kHz: 0,8849 Acquired: 2025/11/02 21.40.59 Total samples: 19098 Equivalent time: 0:15:54 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 5,3 dBr MIN: 0,5 dBr AVE: 3,41 dBr % above 12,2 dBr: 0,0 Last value: 1,0 dBr (2025/11/02 21.40.58) 21.28 21.30 21.32 21.34 21.36 21.38 21.40 0 2 4 6 Pm [dBr]